Why Are There So Many River Rocks In Our Yard?

We have a bit of a geological mystery on our hands… Everywhere we dig we find rather large round rocks – about the size of a basketball (+/-) and quite smooth…

Large smooth rocks

They’re in the back yard. They’re in the cellar (when we dug the trench for the new drain pipes). They seem to be everywhere. They look like river rocks – from a fairly large stream or a small river. But there’s no apparent sign of wetness.

We’ve seen townhouses in Harlem that have streams running under them (one in particular on 141st – on the edge of Hamilton Heights – across the street from the new location of Alexander Hamilton’s Grange) – but there’s no sign of a stream at our place.

So how did so many river rocks get on our property? Could these have been left by glaciers? Are they common in Harlem or in Manhattan in general?

An Artistic Scavenger

Scavenger graffiti in an abandoned Harlem townhouseAs the floors have been going in we we’ve seen that there’s some pretty cool graffiti on the top floor. Well, the top floor is in, so we can finally get a good picture of it…

I’m not sure if the guy was named Scavenger or if he’s just identifying himself as a scavenger. And I don’t know whether it was some person or crew that went through abandoned buildings and salvaged original details or whether it was someone scavenging to support a drug habit (consistent with our house’s reputation back in the day). Either way, as graffiti goes – it’s pretty good.

I’d like to think some of the original details made their way to some place like Demolition Depot or into other Harlem townhouses rather than just being destroyed.

Unfortunately, we can’t save the graffiti – that wall is being insulated and sheetrocked. And honestly, it’s cool to see now, but I wouldn’t want to live with it.

Now that we’re up to the top floor, the next item on the agenda is taking off the roof. They were supposed to do it yesterday, but the weather was really bad. I can’t wait to take photos with no roof. But even more I can’t wait until I can get up to the roof. I want to see if we have a clear view of midtown Manhattan from what will be our roof deck.

Speaking of the roof… It’s amazing it’s still even still there. It was pretty badly burned in a fire in the late ’90s…

Charred roof joists

And here’s are some more gratuitous renovation shots…

This was two days ago as they were putting in the top floor…

Metal joists going into an old brick wall

And this is from this morning – I like the pattern of light on the wall from the old skylight opening…

Top floor in an old townhouse

It’s actually a bit spooky looking down all those flights of stairs to the parlor floor – and it will be even more so as the stairs go up to the roof – it’s over 40 feet down from the roof level to the parlor level. I got a little winded walking up to the top floor today – the house is going to keep me in shape 🙂

We Got Vinyl Windows Past Historic Preservation Review!

The general rule you always hear is you can never put vinyl windows in a historic building – they just won’t be approved. Well, we managed to get them approved – at least in a limited way…

For starters nearly all our windows will be “all wood” – what you’ve heard about no vinyl windows in historic buildings is generally true. The vinyl windows that got approved are 1) in shower areas, and 2) on a wall that’s on a narrow alleyway and not generally visible. We made the argument that putting a wood window in a shower was a bad idea – that plastic windows are much more appropriate since they won’t be affected by the moisture and shower spray. The fact that they’re not visible was also another significant contributing factor in their approval.

Gaulhofer wood windowWe even got exceptions with our “all wood” windows… First, the windows we’re using have protective metal trim on the most vulnerable parts of the window (see image to the right). Even that small amount of metal on a window makes historic preservationists nervous. Usually no cladding is allowed. But we were given an exception for that because 1) there are no original windows – so it won’t stand out as different than something that’s original, and 2) the metal will increase the lifespan of the window – and historic preservationists like things to last a long time. However, to get the exemption for the metal on the windows we needed to have the metal color matched to the wood so it won’t stand out.

It’s also worth mentioning that we’re getting away with not putting in double hung windows (yet another exception to general wisdom about windows in historic buildings). We’re going to have tilt-n-turn windows (they can open completely like a casement window or tilt in at the top). To get that exception we had to have true dividers in the glass so, from the outside of the building, it looks like a double hung window. That’s a big thing to give up for me – I really wanted huge panes of glass.

Now a caveat to all of this is that we are not landmarked by the City. We did not have to go through review by LPC (Landmarks Preservation Commission). Instead, we were reviewed by the New York State Historic Preservation Office and by the National Park Service.

What this shows is that historic preservationists can be flexible. There can be a give and take and if you satisfy their most important concerns you can “get away with” more than you might expect – especially when they’re dealing with National Park Service guidelines rather than LPC rules.

ConEd Residential Gas Rates & Meters

A week ago or so we had a call from our contractor – a guy from ConEd was at the job site talking to the contractor, the plumber and the electrician – and according to him we couldn’t do things the way our architect spec’d. We were planning on two gas meters – one for each unit with heating on our gas meter. He said you couldn’t get a gas meter for an apartment unless it had gas heating. That’s odd, since every apartment I’ve lived in in New York had separately metered gas that didn’t include heating. He also mentioned we could get a better rate if heating was on it’s own meter.

We thought it over, did some investigation and got back to him. Then he got back to us saying he was wrong – that we could have separate meters for each unit. But questioning everything got us to thinking about whether we were happy with our configuration.

Our initial configuration was based on the premise that the best way to encourage energy efficiency is to have people pay for what they use. If it works for electricity, why not do it with gas? With all the questions I started running some numbers…

Take hot water. We expect the tenant will have to spend about $200/year in gas for hot water, but if it were electric it would be $800. Drying clothes and cooking is probably that amount again. That’s only about $33/month for gas, but it’s $133/month for electric – so we can save our tenants $100/month by having gas instead of electricity for hot water and drying. That savings is reduced a bit because ConEd charges $16.80/month just for the meter and the first 3 therms of gas. So the real savings is only about $85/month, but it adds up and lower utilities will keep our tenants happy.

Now, we could just pay for the tenant’s gas – it’s only maybe $35/month (that’s what architect Peter Holtzman does himself and what he recommends). But the thing is, that’s only if the tenant uses their utilities responsibly. We’re not really encouraging conservation if we pay for whatever the tenant uses. So the bottom line is we want to keep the tenant’s gas on a separate meter.

But the discussion with the guy at ConEd raised another question – do we want a dedicated meter/line for heating? If you combine all your gas usage in one line you’ll pay about 79 cents/therm. Dedicated heating lines start at 69 cents/therm for the first 90 therms, then go down to 53 cents per therm. For really large buildings that use a lot of gas the rate gets down to 41 cents per therm, but townhouses don’t use that much gas. I did some searching on Brownstoner and it looks like well-insulated 3,000 sq. ft. townhouses pay about $300/mo for gas heating for the coldest months. We’ll have about 4,000 heated sq. ft., so our bill will be about $400/month. Running the numbers a dedicated line will bring that down to $300/month – but that savings is only during the coldest months. Total yearly savings would be maybe $400. BUT you have to pay an extra meter charge. I haven’t confirmed it, but I think the meter charge is only during the months that require heating. So that reduces the savings by about $150/year. So total savings is about $250/year (guesstimate).

We’re going to ask our contractor/plumber whether there would be an additional charge for the 3rd meter for heating. If takes more than a few years to recoup the cost we’ll just forget about it. But if it’s inexpensive (or they’ll throw it in) then we’ll put it in.

If you’re thinking about a separate line for heating it’s not worth the trouble unless you’ve got a fairly big townhouse. We’re at about 4,000 heated sq. ft. and it’s a coin toss. If you’re at 5,000 sq. ft. I’d definitely recommend it. If you’re place isn’t properly insulated I’d also recommend it. However, if you’re around 3,000 sq. ft. it’s probably not worth the trouble – the cost of the meter will just about wipe out the savings you get from lower rates.

UPDATE:

I’ve tried pretty hard to get an answer from ConEd about whether a dedicated meter for heating makes sense and I can’t find anyone who can answer the question (!) Hardly anyone at ConEd understands their rate structure and the one guy who seemed to know the most seemed to think I was crazy for asking the question. Then he started talking about how many gallons of oil buildings use that typically have dedicated meters for heating. The gallons of oil comment just floored me. Though I think it comes from selling gas service to buildings that currently use oil  (he was a sales guy). He was incapable of talking in terms of size of the building – units, square feet, etc. He couldn’t even tell me what a typical, well-insulated 2 family or 4,000 sq. ft. house pays in heating on cold months. How can they not know that?

I’d really like to know how much to expect in utility bills every month, but it seems it’s just going to be a mystery until it actually happens. Architect Peter Holtzman was nice enough to tell me he paid $2424 last year for all types of gas for his 3 family townhouse on Astor Row. But then a townhouse owner on the Upper West Side said in the comments below that he paid about $800 for just February alone for his 5,000 sq. ft. 3 family. That’s a pretty big range of possible costs. So who knows?

I give up. They seem to just want to put in two meters – one for each apartment. We’ll just stick with that. The separate line for heating seems like a huge uphill battle that’s just not worth the effort. I guess if our heating bills are absurdly high we can investigate installing a third meter down the road. My guess is the bills won’t be all that bad, but I’ll always wonder if they could be a bit lower.

Pleasant Suprise – Bigger Rooms

The past few days we’ve been doing measurements and oddly the building seems to be bigger inside than we were expecting. Since we never could get much above the cellar (which has thicker walls) we didn’t have very precise measurements of the upper floors. Now that we’re actually up in the building we’re finding that the rooms in the front will be about a foot longer than expected, and the ones in the back will be about a foot and a half longer than expected. On top of that everything is about a 1/2 foot wider than the architect was assuming it would be, so we get more space in that direction as well.

When I met Dan I was living in a 350 square foot 5th floor walk-up in Hell’s kitchen (it got really crowded when he moved in with me and my dog). Now our master bedroom and master bath will total 378+/- sq. ft. – bigger than my entire apartment back then, though it”s still a walk-up – of a different sort 🙂

Speaking of the master bedroom here’s a picture of the 3rd floor in our unit looking toward the rear into what will be the master bedroom…

looking towards the master bedroom in townhouse under construction

We measured and we’ll have about 9 foot ceilings on this floor, which will be nice. The ceilings on the parlor floor are about 10′ 5″ – and I’ve forgotten to measure the floor in between – that one should be around 9′ 5″ or 10′ since floor height gets shorter as you go up in townhouses.

And here’s the layout for the floor (with original dimensions). Now it seems the master bedroom will be more like 13.5 x 20 – so about 270 sq. ft. I guess we could make the bathroom a little bigger if we wanted to, but I don’t really see how another 6 inches or a foot will make that big of a difference.

3rd floor of Harlem townhouse with master bedroom

The front “bedroom” will actually be used as a den – that’s where we’ll have our one TV. It will have clerestory windows over the closet to get light in from the bulkhead – should be nice.

The view from the master bedroom isn’t all that inspiring… But hey, you can’t have everything 🙂

View from master bedroom in Harlem townhouse

I can’t wait to see the view from the roof. I’m hoping that building behind us doesn’t block the view of midtown that we’ve seen from the apartment building next door.

Just one more floor and a roof to go and all the structural will pretty much be done!